Loading...
HomeMy WebLinkAboutRequest to Purchase - Central ServicesGRANT COUNTY COMMISSIONERS AGENDA MEETING REQUEST FORM (Must be submitted to the Clerk of the Board by 12:00pm on Thursday) REQUESTING DEPARTMENT: Central Services REQUEST SUBMITTED BY: Tom Gaines CONTACT PERSON ATTENDING ROUNDTABLE: Tom Gaines CONFIDENTIAL INFORMATION: ❑YES M NO DATE: 9-10-26 PHONE: 3276 e : e ► i . . ❑Agreement / Contract DAP Vouchers ❑Appointment / Reappointment DARPA Related ❑ Bids / RFPs / Quotes Award ❑ Bid Opening Scheduled ❑ Boards / Committees ❑ Budget ❑Computer Related ❑County Code ❑Emergency Purchase ❑Employee Rel. ❑ Facilities Related ❑ Financial ❑ Funds ❑ Dearing ® Invoices / Purchase Orders ❑Grants a Fed/State/County ❑ Leases ❑ MOA / MOU [--]Minutes ❑ Ordinances []Out of State Travel ❑ Petty Cash ❑ Policies ❑ Proclamations ❑ Request for Purchase ❑ Resolution ❑ Recommendation ❑ Professional Serv/Consultant ❑ Support Letter ❑ Surplus Req. ❑Tax Levies ❑Thank You's []Tax Title Property ❑WSLCB Request approval of CCLIA 5 from Lydig Construction. Amount is $160,620 and is paid from the Contractors contingency funds. This does not need review from Accounting or the PAO. This should be the last use of Contractor contingency funds. If necessary, was this document reviewed by accounting? ❑ YES W NO If necessary, was this document reviewed by legal? ❑ YES W NO DATE OF ACTION: 91�,S-12-Le APPROVE: DENIED ABSTAIN D2: D3: DEFERRED OR CONTINUED TO: 4/8/24 CONSTRUCTION CONTINGENCY USE AUTHORIZATION CCUA NUMBER: 005 DATE: 6/12/2026 PROJECT NAME: Grant County Jail and Law & Justice Center PROJECT PO NUMBER: CONTRACTOR I CMR: Lydig Construction, Inc. YOU ARE HEREBY AUTHORIZED TO USE THE CONTINGENCY FUNDS FOR THE FOLLOWING WORK: PCO 114 RFI 3 5 8.1 Add VFD's for Kitchen Equipment 21 $7,196 PCO 154 RFI 4672 Door S 102 Requires Exit.Devic $3.1242 PCO 159 RFI-462,, Provide po or and overcurrent pLotection for water heater in K9 $2.1.119 PCO 162 RFI-479, Add contactor to dishwasher to start rooft2p,.Fati FN-3 $25143 PCO 165 -------- ---- RFI-485. Chan electrical re nts to ERV-EOC I and ERV-EV 1 $4)476 PCO 167 RFI-480, Add. power for Water Heater WH-3 $25999 PCO 168 RFI-490, Add 120v power to HPWH for internal freeze _ proteetton $8,351 PCO 169 RFI,-5.010,,Add power to WH-4 in Stora e Evidence $43701 PCO 172 RFI-497 & 520, Add outlets for Evidence stora a coolers & freezers $18,447 PCO 176 RFI-50,1,, Add 12 exit sips, to SE building $9,010 PCO 178 RFI-478, Change. singLe-40A feed to Kitchen Tra table to each 20AduRley, $2,839 PCO 1719 f RFI-502, Provide circuit to HRU-EV-2 shown on mechanical but not electrical Tints $3.1091 PCO 181 Re-route 4" Fire §p±nkler Main in 4 Locations in SE Building conflicting with Electrical Boxes $3,390 PCO 183 RFI-517, Relocate R-Tinter 2owL-',-r/data from 1028 to 1031., add data in 1031 for Homewave $3,1113 PCO 187 .-Changes to Food Service .equi2ment in Commercial Kitchen $33518 PCO 197 Additional excavation to embankment beyond original too & Ua!& report, $66)907 PCO 199 Add thresholds and swee2s to Evidence Buildin Exterior Doors $1.1507 PCO 208 Add disconnects to DOAS & MAUs for internal ,fighting $6.7374 PCO 209 Relocate card reader to opposite door Room 1101 $1,230 PCO 210 Add photo eyes to, vehicle access gates $5,967 ---- - ---------- :t -------------- TOTAL: $1601620 PROPOSED ADJUSTMENTS: THE PROPOSED BASIS OF ADJUSTMENT TO THE CONTINGENCY IS: (LUMP SUM) (CHECK ONE) (CHECK ONE) INCREASE: BUYOUT: DECREASE:X DESIGN OMISSION: X Is PERMITTING AGENCY, OWNER REQUEST: X OTHER: ORIGINAL CONSTRUCTION CONTINGENCY AMOUNT: $3,579,901.00 AMOUNT OF PREVIOUSLY APPROVED CONTINGENCY AUTHORIZATIONS $485,130.00 CONSTRUCTION CONTINGENCY AMOUNT PRIOR TO THIS AUTHORIZATION: 3p094l771.00 AMOUNT OF THIS CONSTRUCTION CONTINGENCY USE: $160,620.00 AMOUNT OF REMAINING CONTINGENCY USE: $299349151.00 i CONSTRUCTION CONTINGENCY USE AUTHORIZATION APPROVALS: CMR: ARCHITECT: OWNER: NAME:",. --` NAME: Don Mixon NAMI Kevin R. Burgess, Chair SIGNED: S I GNE b . __GNED: